{"id":4432,"date":"2026-09-11T07:49:01","date_gmt":"2026-09-11T07:49:01","guid":{"rendered":"https:\/\/atexcom.fr\/?p=4432"},"modified":"2026-09-28T07:56:38","modified_gmt":"2026-09-28T07:56:38","slug":"securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex","status":"publish","type":"post","link":"https:\/\/atexcom.fr\/en\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/","title":{"rendered":"S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu\u2019elle garantit sur un terminal mobile en zone ATEX"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Un op\u00e9rateur qui entre en zone 1 emporte sur lui trois r\u00e9servoirs d&rsquo;\u00e9nergie : une batterie, un \u00e9cran et un \u00e9metteur radio. Dans une atmosph\u00e8re explosive, chacun peut devenir une source d&rsquo;inflammation. La s\u00e9curit\u00e9 intrins\u00e8que rend pourtant ces appareils utilisables sur site. Ce mode de protection, d\u00e9sign\u00e9 par le code Ex i, \u00e9quipe la quasi-totalit\u00e9 des smartphones, radios et montres certifi\u00e9s ATEX. Principe, niveaux de protection, lecture du marquage, contraintes terrain : voici ce qu&rsquo;un responsable HSE ou un acheteur doit en retenir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Limiter l\u2019\u00e9nergie plut\u00f4t que contenir l\u2019explosion : le principe de la s\u00e9curit\u00e9 intrins\u00e8que<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La plupart des modes de protection agissent sur l&rsquo;environnement de l&rsquo;appareil. Ils isolent le circuit ou contiennent une \u00e9ventuelle explosion. La s\u00e9curit\u00e9 intrins\u00e8que suit une logique inverse : elle agit sur le circuit lui-m\u00eame. L&rsquo;appareil ne lib\u00e8re jamais assez d&rsquo;\u00e9nergie pour enflammer le m\u00e9lange pr\u00e9sent autour de lui, m\u00eame en cas de panne.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u00c9tincelle et \u00e9chauffement : les deux sources d\u2019inflammation neutralis\u00e9es<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un \u00e9quipement \u00e9lectrique peut d\u00e9clencher une explosion de deux fa\u00e7ons. La premi\u00e8re est l&rsquo;\u00e9tincelle, produite par un contact, un court-circuit ou une rupture de connexion. La seconde est l&rsquo;\u00e9chauffement d&rsquo;un composant, dont la surface finit par d\u00e9passer la temp\u00e9rature d&rsquo;auto-inflammation du gaz ou de la poussi\u00e8re.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La s\u00e9curit\u00e9 intrins\u00e8que traite ces deux risques. Elle limite le courant, la tension et l&rsquo;\u00e9nergie stock\u00e9e dans le circuit, sous le seuil d&rsquo;inflammation du groupe de gaz vis\u00e9. Pour l&rsquo;hydrog\u00e8ne, ce seuil se situe autour d&rsquo;une vingtaine de microjoules. Elle plafonne aussi la temp\u00e9rature de surface de chaque composant.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>IEC\/EN 60079-11 : la norme qui encadre la conception des appareils Ex i<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La norme IEC\/EN 60079-11 fixe les r\u00e8gles de conception des appareils \u00e0 s\u00e9curit\u00e9 intrins\u00e8que : limites \u00e9lectriques, composants de protection, essais. Elle s&rsquo;inscrit dans la s\u00e9rie IEC\/EN 60079, qui couvre l&rsquo;ensemble des modes de protection pour atmosph\u00e8res explosives. Un fabricant qui revendique le mode Ex i doit d\u00e9montrer la conformit\u00e9 de son appareil \u00e0 cette norme.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Ex ia, Ex ib, Ex ic : trois niveaux de tol\u00e9rance aux d\u00e9fauts<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La s\u00e9curit\u00e9 intrins\u00e8que se d\u00e9cline en trois niveaux. Ce qui les distingue, c&rsquo;est le nombre de d\u00e9fauts que l&rsquo;appareil encaisse sans perdre sa protection.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Ex ia : protection maintenue malgr\u00e9 deux d\u00e9fauts simultan\u00e9s, jusqu&rsquo;en zone 0\/20<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le niveau ia exige que le circuit reste s\u00fbr m\u00eame si deux composants tombent en panne en m\u00eame temps. Les fabricants doublent ou triplent pour cela les composants de protection. C&rsquo;est le seul niveau admis en zone 0, o\u00f9 l&rsquo;atmosph\u00e8re explosive est pr\u00e9sente en permanence.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Ex ib : un d\u00e9faut tol\u00e9r\u00e9, le niveau de r\u00e9f\u00e9rence des terminaux zone 1\/21<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le niveau ib garantit la s\u00e9curit\u00e9 apr\u00e8s un d\u00e9faut unique. Il convient \u00e0 la zone 1, o\u00f9 l&rsquo;atmosph\u00e8re explosive appara\u00eet occasionnellement en fonctionnement normal. La majorit\u00e9 des smartphones, tablettes et radios certifi\u00e9s zone 1\/21 repose sur ce niveau.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Ex ic : protection en fonctionnement normal, r\u00e9serv\u00e9e \u00e0 la zone 2\/22<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le niveau ic assure la protection en fonctionnement normal, sans tol\u00e9rance aux d\u00e9fauts. Il suffit en zone 2, o\u00f9 l&rsquo;atmosph\u00e8re explosive reste rare et de courte dur\u00e9e. Il permet des appareils plus l\u00e9gers et souvent plus abordables.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Niveau<\/strong><\/th><th><strong>D\u00e9fauts tol\u00e9r\u00e9s<\/strong><\/th><th><strong>Zones gaz<\/strong><\/th><th><strong>Zones poussi\u00e8res<\/strong><\/th><th><strong>EPL<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Ex ia<\/td><td>2<\/td><td>0, 1, 2<\/td><td>20, 21, 22<\/td><td>Ga \/ Da<\/td><\/tr><tr><td>Ex ib<\/td><td>1<\/td><td>1, 2<\/td><td>21, 22<\/td><td>Gb \/ Db<\/td><\/tr><tr><td>Ex ic<\/td><td>0<\/td><td>2<\/td><td>22<\/td><td>Gc \/ Dc<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Un <a href=\"https:\/\/atexcom.fr\/en\/\">appareil certifi\u00e9<\/a> pour une zone couvre aussi les zones moins exigeantes. Un terminal Ex ib fonctionne donc en zone 1 comme en zone 2.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pourquoi les terminaux portatifs reposent sur la s\u00e9curi\u00e9 intrins\u00e8que plut\u00f4t que sur l\u2019enveloppe antid\u00e9flagrante<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L&rsquo;enveloppe antid\u00e9flagrante (Ex d) laisse une explosion se produire \u00e0 l&rsquo;int\u00e9rieur du bo\u00eetier, puis la contient. Cette approche exige des parois \u00e9paisses et des joints usin\u00e9s. Elle convient \u00e0 un moteur ou \u00e0 un coffret \u00e9lectrique fixe, pas \u00e0 un appareil qu&rsquo;un technicien tient en main huit heures par jour.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les autres modes de protection posent des limites comparables. La s\u00e9curit\u00e9 augment\u00e9e (Ex e) vise surtout les mat\u00e9riels sans \u00e9tincelles en service normal, comme les bornes de raccordement. La surpression interne (Ex p) suppose une alimentation en gaz de protection. L&rsquo;encapsulage (Ex m) noie des composants dans une r\u00e9sine et compl\u00e8te parfois un circuit Ex i, mais ne suffit pas \u00e0 prot\u00e9ger un terminal entier.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La s\u00e9curit\u00e9 intrins\u00e8que reste donc la seule approche compatible avec les exigences d&rsquo;un terminal mobile : poids contenu, \u00e9cran tactile, connectivit\u00e9 radio, autonomie. Elle prot\u00e8ge l&rsquo;appareil par sa conception, sans le transformer en coffre-fort.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Lire le marquage d&rsquo;un appareil Ex i : l&rsquo;exemple de la montre IS-SW1.1<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le marquage indique pr\u00e9cis\u00e9ment o\u00f9 et comment un appareil peut servir. Prenons celui de la <a href=\"https:\/\/atexcom.fr\/en\/product\/is-sw1-1\/\">montre connect\u00e9e ATEX IS-SW1.1<\/a>, certifi\u00e9e pour les zones 1 et 21.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>II 2G Ex ib IIC T4 Gb, segment par segment<\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>II<\/strong> : groupe d&rsquo;appareils destin\u00e9s aux industries de surface, hors mines.<\/li>\n\n\n\n<li><strong>2G<\/strong> : cat\u00e9gorie 2, atmosph\u00e8re gazeuse. L&rsquo;appareil convient \u00e0 la zone 1.<\/li>\n\n\n\n<li><strong>Ex ib<\/strong> : s\u00e9curit\u00e9 intrins\u00e8que de niveau ib, un d\u00e9faut tol\u00e9r\u00e9.<\/li>\n\n\n\n<li><strong>IIC<\/strong> : groupe de gaz le plus s\u00e9v\u00e8re, qui inclut l&rsquo;hydrog\u00e8ne et l&rsquo;ac\u00e9tyl\u00e8ne. Un appareil IIC couvre aussi les groupes IIA et IIB.<\/li>\n\n\n\n<li><strong>T4<\/strong> : la temp\u00e9rature de surface ne d\u00e9passe jamais 135 \u00b0C.<\/li>\n\n\n\n<li><strong>Gb<\/strong> : niveau de protection du mat\u00e9riel \u00e9lev\u00e9, adapt\u00e9 \u00e0 la zone 1.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La montre porte un second marquage pour les poussi\u00e8res, II 2D Ex ib IIIC T135\u00b0C Db, qui couvre la zone 21. Notre guide pour <a href=\"https:\/\/atexcom.fr\/en\/decryptage-du-marquage-atex\/\">d\u00e9crypter un marquage ATEX<\/a> d\u00e9taille l&rsquo;ensemble des mentions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Qui atteste la s\u00e9curit\u00e9 intrins\u00e8que d\u2019un appareil ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le fabricant ne s&rsquo;autocertifie pas. Pour les appareils \u00e9lectriques de cat\u00e9gorie 1 et 2, la directive 2014\/34\/UE impose un examen UE de type par un organisme notifi\u00e9. Cet organisme v\u00e9rifie la conformit\u00e9 du produit \u00e0 la norme IEC\/EN 60079-11 et d\u00e9livre une attestation<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Batterie, accessoires, recharge : ce que la s\u00e9curit\u00e9 intrins\u00e8que impose sur le terrain<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La certification Ex i porte sur un ensemble pr\u00e9cis : l&rsquo;appareil, sa batterie et ses accessoires approuv\u00e9s. Toute modification de cet ensemble fait perdre la protection, m\u00eame si l&rsquo;appareil semble fonctionner normalement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">La batterie fait partie de la certification : une batterie g\u00e9n\u00e9rique l\u2019annule<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La batterie concentre l&rsquo;essentiel de l&rsquo;\u00e9nergie du terminal. Le fabricant la con\u00e7oit et la certifie avec l&rsquo;appareil, avec ses propres circuits de limitation. Une batterie de remplacement non homologu\u00e9e supprime cette protection. Pour vos stocks de rechange, choisissez toujours une <a href=\"https:\/\/atexcom.fr\/en\/batterie-atex-pour-smartphone-et-radio-autonomie-et-securite\/\">batterie ATEX<\/a> certifi\u00e9e pour votre mod\u00e8le.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Casque, microphone d\u00e9port\u00e9, \u00e9tui : des accessoires certifi\u00e9s avec l\u2019appareil<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tout accessoire raccord\u00e9 au terminal modifie le circuit : il ajoute des c\u00e2bles, des contacts, parfois une source d&rsquo;\u00e9nergie. Un casque anti-bruit \u00e0 s\u00e9curit\u00e9 intrins\u00e8que ou un microphone haut-parleur d\u00e9port\u00e9 ATEX doit figurer dans la liste des accessoires approuv\u00e9s pour votre appareil. Notre gamme d&rsquo;<a href=\"https:\/\/atexcom.fr\/en\/accessoires-atex\/\">accessoires ATEX<\/a> compatibles respecte cette exigence.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Recharge, \u00e9change de batterie, r\u00e9paration : les gestes \u00e0 r\u00e9server hors zone<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les instructions de s\u00e9curit\u00e9 de chaque terminal pr\u00e9cisent les conditions de recharge et d&rsquo;\u00e9change de batterie. Dans la grande majorit\u00e9 des cas, ces op\u00e9rations se font hors zone dangereuse. Il en va de m\u00eame pour toute ouverture du bo\u00eetier. Seul le fabricant ou un r\u00e9parateur agr\u00e9\u00e9 intervient sur un appareil Ex i : une r\u00e9paration non autoris\u00e9e annule la certification.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Smartphone, radio, montre : choisir un terminal Ex i adapt\u00e9 \u00e0 sa zone<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le choix commence par la classification de vos zones. Un appareil Ex ib couvre la zone 1 et la zone 2. Un appareil Ex ic se limite \u00e0 la zone 2. Au-del\u00e0 de ce rep\u00e8re, le marquage reste le seul juge : groupe de gaz, classe de temp\u00e9rature et EPL doivent correspondre aux conditions de votre site.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Chez <a href=\"https:\/\/app.notion.com\/p\/29a645ce8eae8068a3ddd2bd203f3e6d?pvs=21\">Atexcom<\/a>, pour la communication vocale, nos <a href=\"https:\/\/atexcom.fr\/en\/radios-atex\/\">radios ATEX<\/a> couvrent les usages en zone 1 comme en zone 2. Pour les applications m\u00e9tier, la messagerie ou la protection du travailleur isol\u00e9, nos <a href=\"https:\/\/atexcom.fr\/en\/smartphone-telephone-atex-certifies\/\">smartphones ATEX<\/a> certifi\u00e9s combinent s\u00e9curit\u00e9 intrins\u00e8que et environnement Android.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Vous h\u00e9sitez entre deux niveaux de protection ou deux familles de terminaux ?<\/strong> <a href=\"https:\/\/atexcom.fr\/en\/contact\/\">Contactez-nous<\/a> : nos \u00e9quipes vous aident \u00e0 s\u00e9lectionner le mat\u00e9riel adapt\u00e9 \u00e0 vos zones.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Un op\u00e9rateur qui entre en zone 1 emporte sur lui trois r\u00e9servoirs d&rsquo;\u00e9nergie : une batterie, un \u00e9cran et un \u00e9metteur radio. Dans une atmosph\u00e8re explosive, chacun peut devenir une source d&rsquo;inflammation. La s\u00e9curit\u00e9 intrins\u00e8que rend pourtant ces appareils utilisables sur site. Ce mode de protection, d\u00e9sign\u00e9 par le code Ex i, \u00e9quipe la quasi-totalit\u00e9 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4433,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4432","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu&#039;elle garantit en zone ATEX<\/title>\n<meta name=\"description\" content=\"Ex ia, ib, ic, marquage, batterie : ce que la s\u00e9curit\u00e9 intrins\u00e8que garantit sur un smartphone, une radio ou une montre utilis\u00e9s en zone ATEX.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/atexcom.fr\/en\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu&#039;elle garantit en zone ATEX\" \/>\n<meta property=\"og:description\" content=\"Ex ia, ib, ic, marquage, batterie : ce que la s\u00e9curit\u00e9 intrins\u00e8que garantit sur un smartphone, une radio ou une montre utilis\u00e9s en zone ATEX.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/atexcom.fr\/en\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/\" \/>\n<meta property=\"og:site_name\" content=\"ATEXCOM\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-11T07:49:01+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-28T07:56:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/09\/securite-intrinseque-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/#\\\/schema\\\/person\\\/280e49a360ccccfa79dd3f4e75935fee\"},\"headline\":\"S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu\u2019elle garantit sur un terminal mobile en zone ATEX\",\"datePublished\":\"2026-09-11T07:49:01+00:00\",\"dateModified\":\"2026-09-28T07:56:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/\"},\"wordCount\":1462,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/atexcom.fr\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/securite-intrinseque-scaled.jpg\",\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/\",\"url\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/\",\"name\":\"S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu'elle garantit en zone ATEX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/atexcom.fr\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/securite-intrinseque-scaled.jpg\",\"datePublished\":\"2026-09-11T07:49:01+00:00\",\"dateModified\":\"2026-09-28T07:56:38+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/#\\\/schema\\\/person\\\/280e49a360ccccfa79dd3f4e75935fee\"},\"description\":\"Ex ia, ib, ic, marquage, batterie : ce que la s\u00e9curit\u00e9 intrins\u00e8que garantit sur un smartphone, une radio ou une montre utilis\u00e9s en zone ATEX.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/#primaryimage\",\"url\":\"https:\\\/\\\/atexcom.fr\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/securite-intrinseque-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/atexcom.fr\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/securite-intrinseque-scaled.jpg\",\"width\":2560,\"height\":1707},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/atexcom.fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu\u2019elle garantit sur un terminal mobile en zone ATEX\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/#website\",\"url\":\"https:\\\/\\\/atexcom.fr\\\/\",\"name\":\"ATEXCOM\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/atexcom.fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/#\\\/schema\\\/person\\\/280e49a360ccccfa79dd3f4e75935fee\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/atexcom.fr\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu'elle garantit en zone ATEX","description":"Ex ia, ib, ic, marquage, batterie : ce que la s\u00e9curit\u00e9 intrins\u00e8que garantit sur un smartphone, une radio ou une montre utilis\u00e9s en zone ATEX.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/atexcom.fr\/en\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/","og_locale":"en_GB","og_type":"article","og_title":"S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu'elle garantit en zone ATEX","og_description":"Ex ia, ib, ic, marquage, batterie : ce que la s\u00e9curit\u00e9 intrins\u00e8que garantit sur un smartphone, une radio ou une montre utilis\u00e9s en zone ATEX.","og_url":"https:\/\/atexcom.fr\/en\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/","og_site_name":"ATEXCOM","article_published_time":"2026-09-11T07:49:01+00:00","article_modified_time":"2026-09-28T07:56:38+00:00","og_image":[{"width":2560,"height":1707,"url":"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/09\/securite-intrinseque-scaled.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/#article","isPartOf":{"@id":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/"},"author":{"name":"admin","@id":"https:\/\/atexcom.fr\/#\/schema\/person\/280e49a360ccccfa79dd3f4e75935fee"},"headline":"S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu\u2019elle garantit sur un terminal mobile en zone ATEX","datePublished":"2026-09-11T07:49:01+00:00","dateModified":"2026-09-28T07:56:38+00:00","mainEntityOfPage":{"@id":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/"},"wordCount":1462,"commentCount":0,"image":{"@id":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/#primaryimage"},"thumbnailUrl":"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/09\/securite-intrinseque-scaled.jpg","articleSection":["Uncategorized"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/","url":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/","name":"S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu'elle garantit en zone ATEX","isPartOf":{"@id":"https:\/\/atexcom.fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/#primaryimage"},"image":{"@id":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/#primaryimage"},"thumbnailUrl":"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/09\/securite-intrinseque-scaled.jpg","datePublished":"2026-09-11T07:49:01+00:00","dateModified":"2026-09-28T07:56:38+00:00","author":{"@id":"https:\/\/atexcom.fr\/#\/schema\/person\/280e49a360ccccfa79dd3f4e75935fee"},"description":"Ex ia, ib, ic, marquage, batterie : ce que la s\u00e9curit\u00e9 intrins\u00e8que garantit sur un smartphone, une radio ou une montre utilis\u00e9s en zone ATEX.","breadcrumb":{"@id":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/#primaryimage","url":"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/09\/securite-intrinseque-scaled.jpg","contentUrl":"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/09\/securite-intrinseque-scaled.jpg","width":2560,"height":1707},{"@type":"BreadcrumbList","@id":"https:\/\/atexcom.fr\/securite-intrinseque-ex-i-ce-quelle-garantit-en-zone-atex\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/atexcom.fr\/"},{"@type":"ListItem","position":2,"name":"S\u00e9curit\u00e9 intrins\u00e8que (Ex i) : ce qu\u2019elle garantit sur un terminal mobile en zone ATEX"}]},{"@type":"WebSite","@id":"https:\/\/atexcom.fr\/#website","url":"https:\/\/atexcom.fr\/","name":"ATEXCOM","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/atexcom.fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/atexcom.fr\/#\/schema\/person\/280e49a360ccccfa79dd3f4e75935fee","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/atexcom.fr"]}]}},"_links":{"self":[{"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/posts\/4432","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/comments?post=4432"}],"version-history":[{"count":1,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/posts\/4432\/revisions"}],"predecessor-version":[{"id":4434,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/posts\/4432\/revisions\/4434"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/media\/4433"}],"wp:attachment":[{"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/media?parent=4432"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/categories?post=4432"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/tags?post=4432"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}