{"id":4302,"date":"2026-03-27T10:19:46","date_gmt":"2026-03-27T10:19:46","guid":{"rendered":"https:\/\/atexcom.fr\/?p=4302"},"modified":"2026-03-25T10:30:03","modified_gmt":"2026-03-25T10:30:03","slug":"atex-zone-1-zone-2-quel-materiel-choisir","status":"publish","type":"post","link":"https:\/\/atexcom.fr\/en\/atex-zone-1-zone-2-quel-materiel-choisir\/","title":{"rendered":"ATEX zone 1 ou zone 2 : quel mat\u00e9riel choisir ?"},"content":{"rendered":"<p>Vous travaillez sur un site industriel class\u00e9 ATEX et vous devez \u00e9quiper vos \u00e9quipes en appareils mobiles certifi\u00e9s. La premi\u00e8re question \u00e0 trancher : votre site rel\u00e8ve-t-il d&rsquo;une zone 1 ou d&rsquo;une zone 2 ? La r\u00e9ponse d\u00e9termine la cat\u00e9gorie de certification requise, et donc les appareils que vous pouvez utiliser l\u00e9galement et en toute s\u00e9curit\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Zone 1 et zone 2 : ce que \u00e7a change concr\u00e8tement sur le terrain<\/h2>\n\n\n\n<p>Les <a href=\"https:\/\/atexcom.fr\/en\/normes-atex\/\">zones ATEX<\/a> se classent selon la fr\u00e9quence et la dur\u00e9e de pr\u00e9sence d&rsquo;une atmosph\u00e8re explosive. Plus le num\u00e9ro de zone est \u00e9lev\u00e9, moins le risque est fr\u00e9quent.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">La zone ATEX 1 : un risque probable en fonctionnement normal<\/h3>\n\n\n\n<p>En zone 1, une atmosph\u00e8re explosive gazeuse est <strong>susceptible de se former en fonctionnement normal<\/strong>, de fa\u00e7on occasionnelle. On estime sa pr\u00e9sence entre 10 et 1 000 heures par an.<\/p>\n\n\n\n<p>Sur le terrain, la zone 1 correspond typiquement \u00e0 :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>La proximit\u00e9 imm\u00e9diate des vannes, \u00e9vents et ouvertures de remplissage ou de vidange<\/li>\n\n\n\n<li>Les fosses de r\u00e9tention et caniveaux au pied des installations<\/li>\n\n\n\n<li>Les zones autour des cuves de stockage d\u2019hydrocarbures<\/li>\n\n\n\n<li>Les postes de chargement et d\u00e9chargement de liquides inflammables<\/li>\n<\/ul>\n\n\n\n<p>Ces zones exigent des appareils de <strong>cat\u00e9gorie 2<\/strong>, soumis \u00e0 des exigences de certification tr\u00e8s strictes et valid\u00e9s par un organisme notifi\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">La zone ATEX 2 : un risque occasionnel ou de courte dur\u00e9e<\/h3>\n\n\n\n<p>En zone 2, une atmosph\u00e8re explosive gazeuse est <strong>peu probable en fonctionnement normal<\/strong>. Si elle se forme, c&rsquo;est sur une dur\u00e9e courte. On l\u2019estime \u00e0 moins de 10 heures par an.<\/p>\n\n\n\n<p>Sur le terrain, la zone 2 correspond typiquement \u00e0 :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Les emplacements qui entourent les zones 0 et 1<\/li>\n\n\n\n<li>La proximit\u00e9 des brides, raccords de tuyauterie et vannes<\/li>\n\n\n\n<li>Les zones p\u00e9riph\u00e9riques des installations p\u00e9trochimiques ou chimiques<\/li>\n\n\n\n<li>Certains locaux techniques ventil\u00e9s \u00e0 faible risque r\u00e9siduel<\/li>\n<\/ul>\n\n\n\n<p>Ces zones acceptent des appareils de <strong>cat\u00e9gorie 3<\/strong>, aux exigences de certification moins contraignantes et donc g\u00e9n\u00e9ralement moins co\u00fbteux.<\/p>\n\n\n\n<p>La m\u00eame logique s&rsquo;applique aux zones poussi\u00e8res : zone 21 (risque probable) et zone 22 (risque occasionnel), \u00e9quivalentes respectives des zones 1 et 2 pour les atmosph\u00e8res gazeuses.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Quel mat\u00e9riel ATEX pour quelle zone ?<\/h2>\n\n\n\n<p>Un appareil certifi\u00e9 <strong>Zone 1\/21<\/strong> est utilisable en zone 1, en zone 2, et dans leurs \u00e9quivalents poussi\u00e8res. En revanche, un appareil certifi\u00e9 <strong>Zone 2\/22<\/strong> ne peut pas \u00eatre utilis\u00e9 en zone 1, car il n&rsquo;offre pas le niveau de protection requis.<\/p>\n\n\n\n<p>Cette r\u00e8gle a une implication pratique importante : si vos \u00e9quipes se d\u00e9placent entre plusieurs zones de classification diff\u00e9rente sur un m\u00eame site, l&rsquo;appareil zone 1 couvre l&rsquo;ensemble du p\u00e9rim\u00e8tre. C&rsquo;est souvent le choix retenu pour simplifier la gestion du parc mat\u00e9riel.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Appareils pour une zone ATEX 1<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Smartphones Zone 1\/21<\/h3>\n\n\n\n<p>Le <a href=\"https:\/\/atexcom.fr\/en\/product\/is540-1\/\">smartphone IS540.1<\/a> est la r\u00e9f\u00e9rence pour les environnements les plus contraignants. Android 14, processeur Qualcomm Octa Core, 8 Go de RAM, connectivit\u00e9 5G et certification IP68 : il r\u00e9pond aux exigences des op\u00e9rateurs qui travaillent au c\u0153ur des installations p\u00e9trochimiques, chimiques ou sid\u00e9rurgiques.<\/p>\n\n\n\n<p>Pour les besoins plus simples en Zone 1\/21, le <a href=\"https:\/\/atexcom.fr\/en\/product\/is120-1\/\">t\u00e9l\u00e9phone IS120.1<\/a> offre une alternative compacte et \u00e9conomique, avec haut-parleur amplifi\u00e9 et batterie amovible. Pratique pour les interventions longues.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Tablettes Zone 1\/21<\/h3>\n\n\n\n<p>Les techniciens de maintenance qui consultent des plans, des fiches de donn\u00e9es de s\u00e9curit\u00e9 ou des outils de GMAO directement sur le terrain ont besoin d&rsquo;un \u00e9cran plus grand. Les <a href=\"https:\/\/atexcom.fr\/en\/tablettes\/\">tablettes ATEX<\/a> Zone 1\/21, dont la tablette Windows 5G IS945.1, r\u00e9pondent \u00e0 ces usages sans compromis sur la certification.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Appareils pour une zone ATEX 2<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Smartphones Zone 2\/22<\/h3>\n\n\n\n<p>Le <a href=\"https:\/\/atexcom.fr\/en\/product\/is880-2\/\">smartphone IS880.2<\/a> est taill\u00e9 pour les zones p\u00e9riph\u00e9riques et les postes de travail \u00e0 risque mod\u00e9r\u00e9. Fin, l\u00e9ger, \u00e9quip\u00e9 d&rsquo;un processeur Qualcomm Snapdragon Octa Core et de 6 Go de RAM, il convient aux op\u00e9rateurs qui alternent entre zones s\u00e9curis\u00e9es et zones \u00e0 risque au fil de leur journ\u00e9e.<\/p>\n\n\n\n<p>Le <a href=\"https:\/\/atexcom.fr\/en\/product\/is120-2\/\">smartphone IS120.2<\/a> constitue l&rsquo;entr\u00e9e de gamme Zone 2\/22 : fiable, robuste, adapt\u00e9 aux besoins de communication essentiels sur le terrain.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Radios et accessoires Zone 2\/22<\/h3>\n\n\n\n<p>Sur les grands sites industriels, la communication de groupe reste indispensable. Les <a href=\"https:\/\/atexcom.fr\/en\/radios-atex\/\">radios ATEX<\/a> certifi\u00e9es Zone 2\/22 assurent une coordination fluide entre les \u00e9quipes, m\u00eame dans des structures m\u00e9talliques denses. C\u00f4t\u00e9 <a href=\"https:\/\/atexcom.fr\/en\/accessoires-atex\/\">accessoires ATEX<\/a>, micro-haut-parleurs, kits mains-libres et housses renforc\u00e9es compl\u00e8tent l&rsquo;\u00e9quipement terrain.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Vous ne connaissez pas la zone de votre site ?<\/h2>\n\n\n\n<p>La classification des zones figure dans le <strong>DRPCE<\/strong> ou Document Relatif \u00e0 la Protection Contre les Explosions, que chaque chef d&rsquo;\u00e9tablissement a l&rsquo;obligation de tenir \u00e0 jour. Ce document recense l&rsquo;ensemble des zones ATEX du site, leur classification et les exigences mat\u00e9rielles associ\u00e9es.<\/p>\n\n\n\n<p>Si vous n&rsquo;avez pas acc\u00e8s \u00e0 ce document, rapprochez-vous du responsable HSE ou du bureau de s\u00e9curit\u00e9 de votre site. Une fois votre zone identifi\u00e9e, nos \u00e9quipes vous orientent vers les t\u00e9l\u00e9phones ATEX adapt\u00e9s. <strong>Contactez Atexcom pour un <a href=\"https:\/\/www.notion.so\/Fraisepers-32e645ce8eae8007bc93c7c3e5733580?pvs=21\">devis gratuit en 4h<\/a>.<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>Vous travaillez sur un site industriel class\u00e9 ATEX et vous devez \u00e9quiper vos \u00e9quipes en appareils mobiles certifi\u00e9s. La premi\u00e8re question \u00e0 trancher : votre site rel\u00e8ve-t-il d&rsquo;une zone 1 ou d&rsquo;une zone 2 ? La r\u00e9ponse d\u00e9termine la cat\u00e9gorie de certification requise, et donc les appareils que vous pouvez utiliser l\u00e9galement et en toute [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4303,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4302","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ATEX Zone 1 ou Zone 2 : quel mat\u00e9riel choisir ?<\/title>\n<meta name=\"description\" content=\"Zone ATEX 1 ou 2 : la certification de votre appareil mobile doit correspondre \u00e0 votre zonage ATEX. D\u00e9couvrez le mat\u00e9riel certifi\u00e9 et adapt\u00e9 \u00e0 chaque zone.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/atexcom.fr\/en\/atex-zone-1-zone-2-quel-materiel-choisir\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ATEX Zone 1 ou Zone 2 : quel mat\u00e9riel choisir ?\" \/>\n<meta property=\"og:description\" content=\"Zone ATEX 1 ou 2 : la certification de votre appareil mobile doit correspondre \u00e0 votre zonage ATEX. D\u00e9couvrez le mat\u00e9riel certifi\u00e9 et adapt\u00e9 \u00e0 chaque zone.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/atexcom.fr\/en\/atex-zone-1-zone-2-quel-materiel-choisir\/\" \/>\n<meta property=\"og:site_name\" content=\"ATEXCOM\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-27T10:19:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/03\/zone-atex-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/#\\\/schema\\\/person\\\/280e49a360ccccfa79dd3f4e75935fee\"},\"headline\":\"ATEX zone 1 ou zone 2 : quel mat\u00e9riel choisir ?\",\"datePublished\":\"2026-03-27T10:19:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/\"},\"wordCount\":835,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/atexcom.fr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/zone-atex-scaled.jpg\",\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/\",\"url\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/\",\"name\":\"ATEX Zone 1 ou Zone 2 : quel mat\u00e9riel choisir ?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/atexcom.fr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/zone-atex-scaled.jpg\",\"datePublished\":\"2026-03-27T10:19:46+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/#\\\/schema\\\/person\\\/280e49a360ccccfa79dd3f4e75935fee\"},\"description\":\"Zone ATEX 1 ou 2 : la certification de votre appareil mobile doit correspondre \u00e0 votre zonage ATEX. D\u00e9couvrez le mat\u00e9riel certifi\u00e9 et adapt\u00e9 \u00e0 chaque zone.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/#primaryimage\",\"url\":\"https:\\\/\\\/atexcom.fr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/zone-atex-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/atexcom.fr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/zone-atex-scaled.jpg\",\"width\":2560,\"height\":1707,\"caption\":\"Zone ATEX 1 ou 2\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/atex-zone-1-zone-2-quel-materiel-choisir\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/atexcom.fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ATEX zone 1 ou zone 2 : quel mat\u00e9riel choisir ?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/#website\",\"url\":\"https:\\\/\\\/atexcom.fr\\\/\",\"name\":\"ATEXCOM\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/atexcom.fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/atexcom.fr\\\/#\\\/schema\\\/person\\\/280e49a360ccccfa79dd3f4e75935fee\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/atexcom.fr\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ATEX Zone 1 ou Zone 2 : quel mat\u00e9riel choisir ?","description":"Zone ATEX 1 ou 2 : la certification de votre appareil mobile doit correspondre \u00e0 votre zonage ATEX. D\u00e9couvrez le mat\u00e9riel certifi\u00e9 et adapt\u00e9 \u00e0 chaque zone.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/atexcom.fr\/en\/atex-zone-1-zone-2-quel-materiel-choisir\/","og_locale":"en_GB","og_type":"article","og_title":"ATEX Zone 1 ou Zone 2 : quel mat\u00e9riel choisir ?","og_description":"Zone ATEX 1 ou 2 : la certification de votre appareil mobile doit correspondre \u00e0 votre zonage ATEX. D\u00e9couvrez le mat\u00e9riel certifi\u00e9 et adapt\u00e9 \u00e0 chaque zone.","og_url":"https:\/\/atexcom.fr\/en\/atex-zone-1-zone-2-quel-materiel-choisir\/","og_site_name":"ATEXCOM","article_published_time":"2026-03-27T10:19:46+00:00","og_image":[{"width":2560,"height":1707,"url":"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/03\/zone-atex-scaled.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/#article","isPartOf":{"@id":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/"},"author":{"name":"admin","@id":"https:\/\/atexcom.fr\/#\/schema\/person\/280e49a360ccccfa79dd3f4e75935fee"},"headline":"ATEX zone 1 ou zone 2 : quel mat\u00e9riel choisir ?","datePublished":"2026-03-27T10:19:46+00:00","mainEntityOfPage":{"@id":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/"},"wordCount":835,"commentCount":0,"image":{"@id":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/#primaryimage"},"thumbnailUrl":"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/03\/zone-atex-scaled.jpg","articleSection":["Uncategorized"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/","url":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/","name":"ATEX Zone 1 ou Zone 2 : quel mat\u00e9riel choisir ?","isPartOf":{"@id":"https:\/\/atexcom.fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/#primaryimage"},"image":{"@id":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/#primaryimage"},"thumbnailUrl":"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/03\/zone-atex-scaled.jpg","datePublished":"2026-03-27T10:19:46+00:00","author":{"@id":"https:\/\/atexcom.fr\/#\/schema\/person\/280e49a360ccccfa79dd3f4e75935fee"},"description":"Zone ATEX 1 ou 2 : la certification de votre appareil mobile doit correspondre \u00e0 votre zonage ATEX. D\u00e9couvrez le mat\u00e9riel certifi\u00e9 et adapt\u00e9 \u00e0 chaque zone.","breadcrumb":{"@id":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/#primaryimage","url":"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/03\/zone-atex-scaled.jpg","contentUrl":"https:\/\/atexcom.fr\/wp-content\/uploads\/2026\/03\/zone-atex-scaled.jpg","width":2560,"height":1707,"caption":"Zone ATEX 1 ou 2"},{"@type":"BreadcrumbList","@id":"https:\/\/atexcom.fr\/atex-zone-1-zone-2-quel-materiel-choisir\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/atexcom.fr\/"},{"@type":"ListItem","position":2,"name":"ATEX zone 1 ou zone 2 : quel mat\u00e9riel choisir ?"}]},{"@type":"WebSite","@id":"https:\/\/atexcom.fr\/#website","url":"https:\/\/atexcom.fr\/","name":"ATEXCOM","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/atexcom.fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/atexcom.fr\/#\/schema\/person\/280e49a360ccccfa79dd3f4e75935fee","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/da69e738bf17fab4a37fffeb6111125699e034fdcadb00aab1709793a1d6d0e5?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/atexcom.fr"]}]}},"_links":{"self":[{"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/posts\/4302","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/comments?post=4302"}],"version-history":[{"count":1,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/posts\/4302\/revisions"}],"predecessor-version":[{"id":4304,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/posts\/4302\/revisions\/4304"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/media\/4303"}],"wp:attachment":[{"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/media?parent=4302"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/categories?post=4302"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/atexcom.fr\/en\/wp-json\/wp\/v2\/tags?post=4302"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}